Sign In | Join Free | My polstate.com
China Henan Gnee New Materials Co., Ltd. logo
Henan Gnee New Materials Co., Ltd.
Henan Gnee New Materials Co., Ltd.
Verified Supplier

4 Years

Home > VPSA Oxygen Generator >

VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use

Henan Gnee New Materials Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use

Brand Name : GNEE

Certification : SGS

Place of Origin : CHINA

MOQ : ≥1sets

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Delivery Time : Transit time: Est. 17-24 days

Packaging Details : Customer's Requst/customization

Product : VPSA oxygen generator

Keyword : oxygen plant

Filling Rate : 95%

Outlet Pressure : ≥1barg

Atmospheric Dew Point : ≤-60℃

Cooling Method : Air Cooling

Application : Oxygen Generation

Purity : 90-95%

Pressure Rating : High Pressure

Outer Vessel Diameter : 2000 mm

Technology : Vacuum Pressure Swing Adsorption

Condotion : new

Contact Now

VPSA Oxygen Generator (Vacuum Pressure Swing Adsorption Oxygen Generator) realizes the separation of oxygen and nitrogen in the cyclic process of low-pressure adsorption and vacuum desorption through the coordinated work of components such as adsorption towers, vacuum pumps and blowers. Taking air as raw material and relying on the selective adsorption function of molecular sieves, it produces high-purity oxygen. It has the characteristics of low energy consumption, long service life and low operation and maintenance costs, and is the preferred solution for large-scale oxygen supply scenarios.

Product Parameters

Model

Oxygen storage tank

External dimensions

(m)

Total weight

Power
KW

VPSA-1

OG20

6.1×1.5×2.4

1600

5.5

VPSA-2

OG20

6.1×1.5×2.4

1800

5.5

VPSA-3

OG20

6.2×1.5×2.4

2100

5.5

VPSA-4

OG30

6.3×1.7×26

2300

7.7

VPSA-5

OG30

6.4×1.7×2.6

2500

7.7

VPSA-6

OG50

6.5×1.7×3.2

3000

11.7

VPSA-7

OG50

6.7×1.7×3.2

3500

11.9

VPSA-8

OG50

6.7×1.7×3.2

3700

11.9

VPSA-9

OG50

10.5×1.75×3.2

3800

16

VPSA-10

OG50

10.5×1.75×3.2

3850

16

VPSA-11

OG50

10.5×1.75×3.2

3900

16

VPSA-12

QGF0

10.5×1.75×3.2

3950

16.5

VPSA-13

CG50

11×1.75×3.2

4000

20

VPSA-14

0G50

11×1.75×3.2

4100

20

VPSA-15

OG50

11×1.75×3.2

4150

23.5

VPSA-16

OG50

11.5×1.75×3.2

4200

23.5

VPSA-17

OG50

11.5×1.75×3.2

4300

23.5

VPSA-18

OG50

12×1.75×3.2

4500

31.5

VPSA-19

OG50

11.5×1.75×3.2

4600

31.5

VPSA-20

OG50

11.5×1.75×3.2

4650

31.5

VPSA-21

OG50

11.5×1.75×3.2

4900

31.5

VPSA-22

OG50

12.5x1.75x3.2

5000

31.5

VPSA-23

OG60

12.8x1.75x3.25

5200

31.5

VPSA-24

OG60

12.9x1.75x3.25

5300

32.5

VPSA-25

OG60

12.9x1.75x3.25

5350

32.5

VPSA-26

OG60

13x1.75x3.25

5400

32.5

VPSA-27

OG60

13.8x1.75x3.25

5450

39.5

VPSA-28

OG60

13.8x1.75x3.25

5500

39.5

VPSA-29

OG60

13.85.x19x3.25

5550

39.7

VPSA-30

OG60

14.5x1.9x3.25

5800

39.7

VPSA-31

OG60

14.5x1.9x3.25

5850

39.7

VPSA-32

OG60

14.5x1.9x3.25

5800

39.7

VPSA-33

OG60

15x1.9x3.25

5950

47.7

VPSA-34

0060

15x1.9x3.25

6000

47.7

VPSA-35

OG60

15x1.9x3.25

6050

47.7

VPSA-36

OG60

15.5x1.9x3.25

6300

48

VPSA-37

OG60

15.5x1.9x3.25

6350

48

VPSA-38

OG60

15.5x1.9x3.25

6400

48

VPSA-39

OG60

15.5x1.9x3.25

6450

48

VPSA-40

OG60

15.5x1.9x3.25

6500

58

VPSA-41

OG100

15.5x2.3x3.35

7700

58

VPSA-42

OG100

15.5x2.3x3.35

7750

58

VPSA-43

OG100

15.5x2.3x3.35

7800

58

VPSA-44

OG100

15.5x2.3x3.35

7850

58

VPSA-45

OG100

15.5x2.3x3.35

7850

58

VPSA-46

OG100

15.5x2.3x3.35

7900

59

VPSA-47

OG100

15.5x2.3x3.35

7900

59

VPSA-48

OG100

15.5x2.3x3.35

8050

59

VPSA-49

OG100

15.5x2.3x3.35

8200

79

VPSA-50

OG100

15.5x2.3x3.35

8250

79


VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use





















VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use























VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use


Transportation Planning and Packaging Requirements

Transporting VPSA Oxygen Generators requires careful planning to protect precision components, as the equipment consists of fragile parts such as adsorption towers, sensors, and control panels. The first step is to select the appropriate transportation method based on the equipment size and distance: for small units (≤50Nm³/h), road transportation via enclosed van trucks is preferred; for large modular systems (≥1000Nm³/h) or long-distance international transportation, sea freight in containers is more cost-effective.


Packaging is critical to prevent damage during transit. For complete units, the equipment is fixed on a steel base frame (with a load-bearing capacity 1.5 times the equipment weight) and wrapped with moisture-proof film and shock-absorbing foam. The adsorption tower, which is the heaviest component (weighing 500-5000kg depending on capacity), is secured with steel brackets at the top and bottom to prevent tilting or collision.


For split-module transportation (common for large systems), each module is packaged separately: the molecular sieve module is sealed with nitrogen (pressure 0.05MPa) to prevent moisture absorption; the control system is placed in a waterproof and shockproof cabinet with foam padding for sensors and touchscreens; the blower and vacuum pump are wrapped with oil-proof film to avoid leakage of lubricating oil. All packages are labeled with "Fragile", "Keep Upright", "No Stacking" and other signs, and the center of gravity is marked to guide handlers.

Transportation Process Control and On-Site Inspection


During road transportation, the speed of the truck should not exceed 60km/h on highways and 30km/h on rural roads to minimize vibration. Avoid sudden acceleration, braking, or sharp turns, as these can cause displacement of internal components. For long-distance transportation (≥500km), stop every 200km to inspect the packaging—check for loose brackets, damaged film, or oil leakage, and make timely adjustments.


For sea freight, the container should be equipped with moisture-proof agents (1-2kg per cubic meter) to prevent corrosion of metal components due to high humidity in the marine environment. The equipment should be fixed to the container floor with bolts to withstand the rolling and pitching of the ship. Before shipment, conduct a pre-transportation inspection: test the tightness of the adsorption tower, calibrate the sensors, and record the initial status of the equipment.


Upon arrival at the destination, conduct a comprehensive on-site inspection before unloading. Check the packaging for damage, the steel frame for deformation, and the seals of the molecular sieve module for air leakage. Use a crane with a lifting capacity 1.2 times the equipment weight for unloading, and avoid lifting the equipment by the pipelines or control panel. After unloading, place the equipment in the pre-prepared installation site and let it stand for 2-4 hours to allow the internal components to stabilize (especially the lubricating oil in the motor) before installation.


In addition to VPSA Oxygen Generators, we also produce PSA Oxygen Generators, storage tanks, heat exchangers and other products. If you are interested in VPSA Oxygen Systems or other products, please feel free to send an email to info@gneeheatex.com. We will be very happy to serve you.


Product Tags:

≥1barg Outlet Pressure VPSA Oxygen Generator

      

≤-60℃ Dew Point Oxygen Plant

      

Air Cooling Vacuum Pressure Swing Adsorption Oxygen Generator

      
Wholesale VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use from china suppliers

VPSA Oxygen Generator with ≥1barg Outlet Pressure ≤-60℃ Dew Point and Air Cooling for Industrial Use Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Gnee New Materials Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)